Floor-watering system for broilers

Floor-watering system for broilers with drip cup
Aufzucht

Perfect water supply for all age groups

The central element of the floor-watering system is the TOP-Nipple.
The combination of TOP-Nipple and Drip Cup ensures a dry manure and a optimum flow for every age!

 

 

 

The height of the drinking lines have to be adjusted to the size of the birds!

They should have to stretch slightly to reach the nipples!
A table for the height of the drinker line for the floor-watering system, which is included in each delivery, makes it easy to find the right height option from the first day on.

Please choose an element:
leer

Elements:


The LUBING Floor-Watering System consists of the following elements:

1. Water Supply
2. Drinking Elements
3. Breather Unit
4. Suspension

1. Water Supply:

With the main water supply we achieve an optimal water quality for a long life of the drinking trough. The water should have drinking water quality. It is absolutely necessary to filter the water. Water is supplied via the ball tank or over a pressure regulator with integrated flush facility. Both versions are available for the end connection or the middle connection.

2. Drinking Elements:

The drinking lines are supplied in assembled elements of 3 m length. These elements are then coupled together through the length of the house.

3. Breather Unit:

A breather revolving unit is installed at the end of the drinking line for the ventilation and the flush.

4. Suspension:

The suspension of the drinking lines is supplied via hangers which are stuck on the aluminium profiles approx. every 3 m. These hangers are connected with the suspension lines via ceiling pulleys with the central hoisting cable. Then the drinking line can be adjusted to the required height by the hand or middle winches or it can be winched up easily to the ceiling for emptying and cleaning.

 

GefälleDruckminderer

on the left:
The LUBING slope regulator for the use in uneven houses.


on the right: The LUBING pressure regulator can also be installed in the middle of a water line according to the lenght house.

 

Main facts at a glance:
Recommended number of birds per nipple*:
Normal mast / fattening up to 2 kg: 18-20 animals / nipple
Heavy / fat mast up to 3 kg: 15-18 animals / nipple
* The number of animals per nipple has to be reduced when the animals are heavy, in hot climate zones and in dependence of the light programme. Pay attention to national / regional regulations!
Heavy broilers need Starter Cups in the last 2 weeks. Recommendation: 3 pcs. per element
(Several) versions of our delivery programme:
Rearing (until 20th week)  
article number 4038 08 nipples / 3 m-element
article number 4037 10 nipples / 3 m-element
article number 4036 12 nipples / 3 m-element
article number 4039 15 nipples / 3 m-element
   
Layout :
We recommend a drinking line every 2,5 to 3,5 m width of a house.
Fundamentally, their should always be installed one more drinking line than feeding lines.
  front side installation max. length
of line (m)
middle installation max. length
of line (m)
Ball tank 4221-00 60 (40)** 4223-00 120(80)**
Pressure regulator 3201-00 60 (40)** 3206-00 120(80)**
** at light programme

 

 

Floor-watering system for broilers without drip cup
Aufzucht

LUBING TOP-Nipple reduced Art. 4077
LUBING TOP-Combinipple reduced
Art. 4078

Perfect water supply for all age groups

The central element of the floor-watering system is the TOP-Nipple reduced. The reduced flow of this nipple ensures a dry manure without drip cups. The height of the drinking lines have to be adjusted to the size of the birds! They should have to stretch slightly to reach the nipples! A table for the height of the drinker lines, which is included in each delivery, makes it easy to find the right height option from the first day on.

Please choose an element:
Stall Broiler leer

Elements:

The LUBING Floor-Watering System consists of the following elements:

1. Water Supply
2. Drinking Elements
3. Breather Unit
4. Suspension


lubing
Alternatively also a steel
tube can be used above
the nipple pipe.

1. Water Supply:

With the main water supply we achieve an optimal treatment of water for a long life of the drinking system. The water should have drinking water quality. It is absolutely necessary to filter the water. Water is supplied via the pressure regulator with integrated flush facility. This version is available for the end connection or the middle connection.

 

 

2. Drinking Elements:

The drinking lines are supplied in assembled elements of 3 m length. These elements are then coupled together through the length of the house.

3. Breather Unit:

A breather revolving unit is installed at the end of the drinking line for the ventilation and the flush.

4. Suspension:

The suspension of the drinking lines is supplied via hangers which are stuck on the aluminium profiles approx. every 3 m. These hangers are connected with the plastic rope via ceiling pulleys with the central hoisting cable. Then the drinking line can be adjusted to the required height by the hand or ceiling winches or it can be winched up easily to the ceiling for emptying and cleaning.

lubing

on the left:
The LUBING slope regulator for the use in uneven houses.

 

on the right:
The LUBING pressure regulator can also be installed in the middle of a water line according to the length of the house.

lubing

Main facts at a glance:
Recommended number of birds per nipple*:
Broiler 8 - 10 animals / nipple
Heavy / fat mast up to 3 kg: 15-18 animals / nipple
* The number of animals per nipple has to be reduced in hot climate zones and
in dependence of the light-/waterprogram.
Pay attention to national / regional regulations!
Versions of our delivery programme:
article number 4080-1 08 nipples / 3 m - element
article number 4081-1 10 nipples / 3 m - element
article number 4082-1 12 nipples / 3 m - element
article number 4083-1 15 nipples / 3 m - element
   
Layout :
We recommend a drinking line every 2,5 to 3,5 m width of a house.
Fundamentally, their should always be installed one more drinking line than food lines.
  front installation max. length
of line (m)
middle installation max. length
of line (m)
Pressure regulator 4281 60 (40)** 4282 120(80)**
** at light-/waterprogramme