Floor-watering system

Floor-watering system guarantees optimum water supply
Aufzucht
LUBING TOP-Nipple
with sidewarts action
for rearing.
For combined rearing and layer use with TOP-Nipple Art. 4022; for layers from the 20th week with stainless steel Nipple Art. 4001


 

 

 


Please choose an element:
Stall Eltern leer

Elements:

The LUBING Floor-watering System consists of the following elements:

1. Water Supply
2. Drinking Elements
3. Breather Unit
4. Suspension

1. Water Supply:

With the main water supply we achieve an optimal waterquality for a long life of the drinking system. The water should have drinking water quality. It is absolutely necessary to filter the water. Water is supplied via the ball tank or over a pressure regulator with integrated flush facility. Both versions are available for the end connection or the middle connection.

2. Drinking Elements:

Nippel
The TOP-Nipple with
drip cup. The drip cup ensures
dry manure.

The drinking lines are supplied in assembled elements of 3 m length. These elements are then coupled together through the length of the house.

3. Breather Unit:

A breather revolving unit is installed at the end of the drinking line for the ventilation and the flush.

4. Suspension:

The suspension of the drinking lines is supplied via hangers which are stuck on the aluminium profiles approx. every 3 m. These hangers are connected with the plastic rope via ceiling pulleys with the central hoisting cable.

Then the drinking line can be adjusted to the required height by the hand or ceiling winches or it can be winched up easily to the ceiling for emptying and cleaning.

 

GefälleDruckminderer

on the left:
The LUBING slope regulator for the use in uneven houses.

on the right:
The LUBING pressure regulator can also be installed in the middle of a water line according to the lenght house.

 

Main facts at a glance
Recommended number of birds per nipple*:
breeder rearing 10-15 Nipples
breeder 10-12 Nipples
**The number of animals per nipple has to be reduced when the animals are heavy, in hot climate zones and in dependence of the light-/waterprogramme. Pay attention to national / regional regulations!
(Several) versions of our delivery programme:
rearing breeder (up to approx. week 20)  
article number 4055 08 nipple / 3 m-Element
article number 4056 10 nipple / 3 m-Element
article number 4057 12 nipple / 3 m-Element
article number 4058 15 nipple / 3 m-Element
   
breeder (from week 20)  
article number 4065 08 nipple / 3 m-Element
article number 4066 10 nipple / 3 m-Element
article number 4067 12 nipple / 3 m-Element
article number 4068 15 nipple / 3 m-Element
   
Layout :
We recommend a drinking line every 2,5 to 3,5 m width of a house.
Fundamentally, their should always be installed one more drinking line than food lines.
  front installation max. length
of lines (m)
middle installation max. length
of line (m)
Pressure regulator 3201-00 40 3206-00 120(80)**
** at light-/waterprogramme